Technical parameters
	
 
| 
				 Rated voltage  | 
			
				 400V or 660V or customized  | 
		
| 
				 Rated capacitor voltage  | 
			
				 400V,440V,450V,480V,525V or customized  | 
		
| 
				 Rated frequency  | 
			
				 50Hz  | 
		
| 
				 Dielectric test  | 
			
				 50Hz 3KV,60s  | 
		
| 
				 Cooling method  | 
			
				 natural air  | 
		
| 
				 Ambient temperature  | 
			
				 -25 to +40ºC  | 
		
| 
				 Protection class  | 
			
				 IP00 indoor mounting  | 
		
| 
				 Inductance tolerance  | 
			
				 0/+5%  | 
		
| 
				 Elevation above sea level  | 
			
				 ≤2000m a.s.l.  | 
		
| 
				 Reference standard  | 
			
				 GB/T10229,JB5346,IEC289  | 
		
| 
				 Insulation class  | 
			
				 F,H or C as customized  | 
		
| 
				 Design method  | 
			
				 Single phase or three phase  | 
		
| 
				 Maximum humidity  | 
			
				 95%  | 
		
| 
				 Blocking factor p%  | 
			
				 6%,7%,12%,14% or as customized  | 
		
| 
				 Noise level  | 
			
				 <50dB  | 
		
| 
				 Linearity  | 
			
				 1.55-2.2In  | 
		
| 
				 Winding material  | 
			
				 Copper wire/ Aluminum Foil  | 
		
| 
				 Terminals  | 
			
				 Copper or Aluminum terminals  | 
		
| 
				 Temp. rise at rated current  | 
			
				 Less than 65K  | 
		
| 
				 Temp. rise at max. working current  | 
			
				 Less than 95K  | 
		


Series reactor basic parameters & dimensions
	
	
| Model | Capacitor capacity (KVAR) | Reactor capacity (KVAR) | 
				Current (A)  | 
			
				 Inductance (mH)  | 
			
				Dimension L×W×H (mm)  | 
			
				Installation size (mm)  | 
			Insulation Grade | 
| CKSG-0.6/0.45-6% | 10 | 0.60 | 12.83 | 3×3.87 | 190×160×170 | 150×85,4-φ8 | H | 
| CKSG-0.9/0.45-6% | 15 | 0.90 | 19.24 | 3×2.58 | 190×170×170 | 150×95,4-φ8 | H | 
| CKSG-1.2/0.45-6% | 20 | 1.20 | 25.66 | 3×1.94 | 190×170×170 | 150×95,4-φ8 | H | 
| CKSG-1.5/0.45-6% | 25 | 1.50 | 32.07 | 3×1.55 | 230×150×190 | 190×75,4-φ8 | H | 
| CKSG-1.8/0.45-6% | 30 | 1.80 | 38.49 | 3×1.29 | 230×160×190 | 190×85,4-φ8 | H | 
| CKSG-2.4/0.45-6% | 40 | 2.40 | 51.31 | 3×0.97 | 230×170×190 | 190×95,4-φ8 | H | 
| CKSG-3.0/0.45-6% | 50 | 3.00 | 64.14 | 3×0.77 | 265×210×230 | 200×110,4-φ8 | H | 
| CKSG-3.6/0.45-6% | 60 | 3.60 | 76.97 | 3×0.65 | 265×210×230 | 200×110,4-φ8 | H | 
| Model | Capacitor capacity (KVAR) | Reactor capacity (KVAR) | 
					Current (A)  | 
				
					 Inductance (mH)  | 
				
					Dimension L×W×H (mm)  | 
				
					Installation size (mm)  | 
				Insulation Grade | 
| CKSG-0.7/0.45-7% | 10 | 0.70 | 12.83 | 3×4.52 | 190×160×170 | 150×85,4-φ8 | H | 
| CKSG-1.05/0.45-7% | 15 | 1.05 | 19.24 | 3×3.01 | 190×170×170 | 150×95,4-φ8 | H | 
| CKSG-1.4/0.45-7% | 20 | 1.40 | 25.66 | 3×2.26 | 230×150×190 | 190×75,4-φ8 | H | 
| CKSG-1.75/0.45-7% | 25 | 1.75 | 32.07 | 3×1.81 | 230×160×190 | 190×85,4-φ8 | H | 
| CKSG-2.1/0.45-7% | 30 | 2.10 | 38.48 | 3×1.51 | 230×170×190 | 190×95,4-φ8 | H | 
| CKSG-2.8/0.45-7% | 40 | 2.80 | 51.31 | 3×1.13 | 230×180×190 | 190×105,4-φ8 | H | 
| CKSG-3.5/0.45-7% | 50 | 3.50 | 64.14 | 3×0.90 | 265×220×230 | 200×120,4-φ8 | H | 
| CKSG-4.2/0.45-7% | 60 | 4.20 | 76.97 | 3×0.75 | 265×220×230 | 200×120,4-φ8 | H | 
| Model | Capacitor capacity (KVAR) | Reactor capacity (KVAR) | 
				Current (A)  | 
			
				 Inductance (mH)  | 
			
				Dimension L×W×H (mm)  | 
			
				Installation size (mm)  | 
			Insulation Grade | 
| CKSG-1.2/0.525-12% | 10 | 1.20 | 11.00 | 3×10.53 | 190×170×170 | 150×95,4-φ8 | H | 
| CKSG-1.8/0.525-12% | 15 | 1.80 | 16.50 | 3×7.02 | 230×160×190 | 190×85,4-φ8 | H | 
| CKSG-2.4/0.525-12% | 20 | 2.40 | 22.00 | 3×5.27 | 230×170×190 | 190×95,4-φ8 | H | 
| CKSG-3.0/0.525-12% | 25 | 3.00 | 27.50 | 3×4.21 | 265×210×230 | 200×110,4-φ8 | H | 
| CKSG-3.6/0.525-12% | 30 | 3.60 | 32.99 | 3×3.51 | 265×210×230 | 200×110,4-φ8 | H | 
| CKSG-4.8/0.525-12% | 40 | 4.80 | 43.99 | 3×2.63 | 265×220×230 | 200×130,4-φ8 | H | 
| CKSG-6.0/0.525-12% | 50 | 6.00 | 54.99 | 3×2.11 | 290×180×280 | 200×130,4-φ8 | H | 
| CKSG-7.2/0.525-12% | 60 | 7.20 | 65.99 | 3×1.76 | 290×200×280 | 200×130,4-φ8 | H | 
| Model | Capacitor capacity (KVAR) | Reactor capacity (KVAR) | 
					Current (A)  | 
				
					 Inductance (mH)  | 
				
					Dimension L×W×H (mm)  | 
				
					Installation size (mm)  | 
				Insulation Grade | 
| CKSG-1.4/0.525-14% | 10 | 1.40 | 11.00 | 3×12.29 | 230×150×190 | 190×75,4-φ8 | H | 
| CKSG-2.1/0.525-14% | 15 | 2.10 | 16.49 | 3×8.19 | 230×170×190 | 190×95,4-φ8 | H | 
| CKSG-2.8/0.525-14% | 20 | 2.80 | 21.99 | 3×6.15 | 230×180×190 | 190×105,4-φ8 | H | 
| CKSG-3.5/0.525-14% | 25 | 3.50 | 27.49 | 3×4.92 | 265×220×230 | 200×120,4-φ8 | H | 
| CKSG-4.2/0.525-14% | 30 | 4.20 | 32.99 | 3×4.10 | 265×220×230 | 200×120,4-φ8 | H | 
| CKSG-5.6/0.525-14% | 40 | 5.60 | 43.98 | 3×3.07 | 265×240×230 | 200×140,4-φ8 | H | 
| CKSG-7.0/0.525-14% | 50 | 7.00 | 54.98 | 3×2.46 | 290×190×280 | 200×140,4-φ8 | H | 
| CKSG-8.4/0.525-14% | 60 | 8.40 | 65.98 | 3×2.05 | 290×210×280 | 200×140,4-φ8 | H | 
Note: The above specifications are common specifications for reference only. Reactors of other voltage levels, different capacities and different reactance rates can be manufactured according to user's requirements.
Contact: Henry Zhou
Phone: +86-13626551830
Tel: +86-577-55773828
Whatsapp: +86-13626551830
Email: reelen@reelen.com.cn
Add: Xiangyang Industrial Zone,Liushi Town, Yueqing, Zhejiang, China. 325619